Zaps and Patches for PHOENIX and PREFERENCE
Release 7.9.1
Click on zap number to download. Contact Pathlore
Technical Support for additional information on applying the
fix.
s791001
PHO/PREF
GSPCOPY RESTORE requests may abend with an S0C1 program
check if the requested course/volume is restored to a different
program file than where it previously existed.
s791003
PHO/PREF
If you are experiencing CICS Storage Violations due to
an invalid FREEMAIN length for a transaction COMMAREA
after upgrading to CICS TS 3.1, then you may be
experiencing this problem.
s791004
PHO/PREF
Writers or Authors using the extended block highlighting
feature may have a problem setting and unsetting
extended highlighting.
s791005
PHO/PREF
Our CICS XZCIN Exit was erroneously detecting that a TCT entry was
flagged as being a "Permanent Transaction Code" due to a change in
the TCT layout with CICS TS 3.1. Since TCT's are generally
auto-installed, it is highly unlikely that "Permanent Transaction
Codes" are used.
This ZAP has been created to eliminate
PHOENIX/PREFERENCE support of "Permanent Transaction Code"
processing and their resultant anomalies. For example, users may be
unable to continue in their application after returning from a help
or screen capture request.
s791006
PHO/PREF
If you disable the allocation of User Key
storage in
CSA via "ALLOWUSERKEYCSA(NO)", then a System B78 Code
X'5C' will occur.
The Code X'5C' indicates that a program
attempted to
obtain User Key (8-F) storage from a CSA subpool and
ALLOWUSERKEYCSA(NO) was specified.
s791007
PHO/PREF
With the release of z/OS 1.9 the PCCA
control block
can optionally be moved about the 16 Meg line. If
you have the PCCA control block moved above the
16 Meg line, this zap must be applied for
PHOENIX/PREFERENCE to be compatible with this change.
Coreq: Apply this PTF, PTF S791010
and PTF S791008 if you are using our CICS interface.
s791008
PHO/PREF
With the release of z/OS 1.9 the PCCA
control block
can optionally be moved about the 16 Meg line. If
you have the PCCA control block moved above the
16 Meg line, this zap must be applied for
PHOENIX/PREFERENCE to be compatible with this change.
Coreq: Apply this PTF, PTF S791007
and PTF S791010.
S791010
PHO/PREF
With the release
of z/OS 1.9 the PCCA control block can optionally be moved
about the 16 Meg line. If you have the PCCA control block
moved above the 16 Meg line, this zap must be applied for
PHOENIX/PREFERENCE to be compatible with this change.
Z791001
PHO
Bypass signon processing displays 'Invalid Curriculum' message when no course name or invalid course name detected in bypass signon string. This PTF restores navigation to signon screen under these bypass conditions.
Z791002 - NOTE: This is a MANDATORY
zap.
PREF
Wrong help screen may be displayed for popup help requests. Error occurs for any index term used to navigate to popup help, where other index terms share the first two characters of term used.
Z791003
PREF
When writers delete or replace index terms in reference items, the
replaced or deleted term may not be removed from the reader index
file. This ptf corrects writer index editing.
The writer 'index' command can be used to restore and correct index
as circumvention.
Z791004
PREF
When writers copy or delete reference items, associated
index terms may not be removed from the reader index
or may appear out of alphabetical order in this list.
This ptf ensures that item copy and delete will remove
and sort reader index terms correctly.
A circumvention is to use the writer 'index' command
to restore and correct the reader index.
Z791005
PHO/PREF
Supervisors may encounter GD024 SYSTEM ERROR at
$gsupr-lmscbt-1-3 or rmscbr-1-3 while navigating within
the PHOENIX Course Manager or the PREFERENCE Volume
Manager. The error may occur after accessing the
Users Inactive facility.
Z791006
PREF
Group volume readers may be presented with index list
instead of an item after multiple index or hypertext
look-ups. This occurs even though a valid index term
is requested.
Z791007
PREF
Group volume reader F13 Return option does not return
to previous screen after hypertext look-up. This
problem occurs after application of z791006.
Z791008
PREF
Index terms may be stored out of sequence in reader
index files.
As circumvention, the 'index' command can be used
to correctly reconstruct reader index files.
Z791009
PREF
When tagged F17 Capture item contains one or more
index tags ('i1'), subsequent items are imported with
all tagged components ('it', 'i1', 'h1', etc.) treated
as text.
Z791010
PREF
When attempting tagged import (F17 Capture reference
material) and out of space condition occurs, writers
encounter GD001 indirect addressing error at $gs001-
nosave-1-14. Error occurs when writer exits message
to reassemble and add space.'
Z791012
PREFERENCE
When readers attempt to use F13 Return in a volume
containing embedded components, navigation does not
occur and menu displays item '-1 of 32,123'.
This update corrects navigation and display of item
number when utilizing F13 Return functionality.
Z791013
PHOENIX
Student exit from PHOENIX course accessed through
Pathlore LMS (PHOENIX Connector) incorrectly specifies
whether the course is 'complete' or 'in progress' and
passes the incorrect information to the LMS.
This PTF results in correct 'complete'/'in progress'
student information passed to the LMS.
|